OBJECTIVE: This post hoc analysis assessed continuous glucose monitoring (CGM)-based metrics and hypoglycemia duration with once-weekly insulin icodec versus once-daily basal insulin analogs in insulin-experienced individuals with long-standing type 2 diabetes from two 26-week phase 3a trials (ONWARDS 2 and ONWARDS 4).

RESEARCH DESIGN AND METHODS: Time in range (TIR) (3.9-10.0 mmol/L), time above range (TAR) (>10.0 mmol/L), and time below range (TBR) (<3.9 mmol/L and <3.0 mmol/L) were assessed during three CGM time periods (switch [weeks 0-4], end of treatment [weeks 22-26], and follow-up [weeks 27-31]) for icodec versus comparators (ONWARDS 2, insulin degludec [basal regimen]; ONWARDS 4, insulin glargine U100 [basal-bolus regimen]) using double-blind CGM data. CGM-derived hypoglycemic episode duration (<3.9 mmol/L) was assessed.

RESULTS: In both trials, there were no statistically significant differences in TIR, TAR, or TBR (<3.0 mmol/L) for icodec versus comparators across all time periods. In the end-of-treatment period, mean TIR was 63.1% (icodec) vs. 59.5% (degludec) in ONWARDS 2 and 66.9% (icodec) vs. 66.4% (glargine U100) in ONWARDS 4. Mean TBR <3.9 mmol/L and <3.0 mmol/L remained within recommended targets (<4% and <1%, respectively) across time periods and treatment arms. Hypoglycemic episode duration (<3.9 mmol/L) was comparable across time periods and treatment arms (median duration <=40 min).

CONCLUSIONS: In insulin-experienced participants with long-standing type 2 diabetes, CGM-based TIR, TAR, and CGM-derived hypoglycemia duration (<3.9 mmol/L) were comparable for icodec and once-daily basal insulin analogs during all time periods. TBR remained within recommended targets.

(C) 2024 by the American Diabetes Association, Inc.