The following article requires a subscription:



(Format: HTML, PDF)

Objectives: To determine the effectiveness of a novel sonic toothbrush in reducing plaque and in maintenance of gingival health when compared to a standard manual brush.

Methods: This study was a block-randomized, examiner-blind, two-treatment, parallel group, single centre clinical investigation. A total of 84 subjects were enrolled and randomly assigned to receive either the Panasonic EW-DL90 or an American Dental Association-endorsed manual toothbrush. Subjects were instructed to follow a twice-daily brushing regimen without flossing. Plaque levels and gingival health were assessed at baseline and after 1 and 3 weeks of treatment using the Turesky Modification of the Quigley-Hein Plaque Index and the Papillary Bleeding Score.

Results: Subjects assigned to the EW-DL90 group had significantly lower plaque levels after 1 and 3 weeks of treatment than those in the manual group (P = 0.003 and 0.0035, respectively). Both groups showed a reduction in plaque levels at Week 3 relative to baseline. The EW-DL90 group had significantly lower gingival inflammation scores after 1 week of treatment (P = 0.0293), but there was no difference between groups after 3 weeks of treatment.

Conclusion: The EW-DL90 toothbrush safely and effectively removes more plaque than a standard manual toothbrush. Improvement in gingival inflammation was observed after 1 week of treatment. There was no difference in Papillary Bleeding Score between the two groups after 3 weeks of treatment.

Clinical significance: The newly developed sonic brush (Panasonic EW-DL90) tested in this study was found to be more effective than a manual toothbrush at plaque removal. The papillary bleeding scores were significantly lower in the sonic brush group after 1 week of product use. After 3 weeks of product use, both treatment groups had similar papillary bleeding scores almost returning to baseline values.

(C) 2014 John Wiley & Sons, Ltd