Information de reference pour ce titreAccession Number: | 00130478-200101000-00003.
|
Author: | Kapasi, Munir MD; Fujino, Yuji MD; Kirmse, Max MD; Catlin, Elizabeth A. MD; Kacmarek, Robert M. PhD, RRT FCCM
|
Institution: | From the Pediatric Service and Respiratory Care Department of the Massachusetts General Hospital and Harvard Medical School, Boston, MA.
|
Title: | |
Source: | Pediatric Critical Care Medicine. 2(1):9-16, January 2001.
|
Abstract: | Objective: This study compares patient-ventilator synchrony, work of breathing and patient effort in neonates during different modes of patient-triggered ventilation.
Design: Clinically stable neonates received intermittent mandatory ventilation (IMV), synchronized intermittent mandatory ventilation (SIMV), pressure assist/control ventilation (A/C), and pressure support ventilation (PSV) in a random order for 20 mins. With each mode patient-ventilator synchrony, work of breathing, and patient effort were evaluated.
Setting: Neonatal level III intensive care unit of a university hospital.
Measurements and Results: Seven clinically stable neonates (31.4 +/- 2 wks gestation, weighing 1.49 +/- 0.38 kg) were randomly ventilated with the above four modes using a Bird VIP ventilator. Esophageal pressure, airway pressure, and flow were measured using a CP-100 neonatal monitor (Bicore). Data for five consecutive breaths in each mode were analyzed. Patient effort and work of breathing differed significantly among modes of ventilation. The inspiratory pressure time product was least with A/C (0.54 +/- 0.29 cm H2O[middle dot]sec) and increased with PSV (0.60 +/- 0.39 cm H2O[middle dot]sec), SIMV (1.46 +/- 0.55 cm H2O[middle dot]sec), and IMV (2.74 +/- 1.05 cm H2O[middle dot]sec) (p < .05). A similar trend was observed for work of breathing, with work least during A/C (0.07 +/- 0.04 joules per liter [J/L]), followed by PSV (0.17 +/- 0.14 J/L), SIMV (0.33 +/- 0.13 J/L), and IMV (0.41 +/- 0.16 J/L) (p < .05). Marked dyssynchrony between patient-initiated and ventilator-initiated inspiration occurred only during IMV.
Conclusion: Asynchrony can be avoided by the use of assisted, patient triggered modes of ventilation and, of the available modes, pressure A/C results in the least effort and work of breathing for clinically stable neonates.
(C) 2001 Lippincott Williams & Wilkins, Inc.
|
Author Keywords: | assisted ventilation; work of breathing; pressure-time product modes of ventilation; pressure support; pressure assist; control; intermittent mandatory ventilation.
|
References: | 1. Greenough A, Morley CJ, Davis J: Interaction of spontaneous respiration with artificial ventilation in preterm babies. J Pediatr 1983; 103: 769-773
2. Greenough A Morley CJ Johnson P: An active respiratory reflex in preterm ventilated infants. In: The Physiological Development of the Fetus and Newborn. Jones CT, Nathanielsz PW, (Eds). New York, Academic Press, 1985, pp 259-262
3. Henry GW, Stevens CS, Schreiner RL, et al: Respiratory paralysis to improve oxygenation and mortality in large newborn infants with respiratory distress. J Pediatr Surg 1979; 14:6: 761-766
4. Stark AR, Bascom R, Frantz ID III: Muscle relaxation in mechanically ventilated infants. J Pediatr 1978; 94: 3:439-443
5. Greenough A, Wood S, Morley CJ, et al: Pancuronium prevents pneumothoraces in ventilated premature babies who actively expire against positive pressure ventilation. Lancet 1984; i: 1-4
6. Perlman LM, Goodman S, Kreusser KL, et al: Reduction in intraventricular hemorrhage by elimination of fluctuating cerebral blood flow velocity in preterm infants with respiratory distress syndrome. N Engl J Med 1985; 312: 1353-1357
7. Rennie JM, South M, Morley CJ: Cerebral blood flow velocity variability in infants receiving assisted ventilation. Arch Dis Child 1987; 62: 1247-1251
8. Pollitzer MJ, Shaw DG, Reynolds EOR, et al: Pancuronium during mechanical ventilation speeds recovery of lungs of infants with hyaline membrane disease. Lancet 1981; i: 346-348
9. Shaw NJ, Cook RWI, Gill AB, et al: Randomized trial of routine versus selective paralysis during ventilation for neonatal respiratory distress syndrome. Arch Dis Child 1993; 69: 479-482
10. Greenough A, Milner AD: Respiratory support using patient triggered ventilation in the neonatal period. Arch Dis Child 1992; 67: 69-71
11. Field D, Milner AD, Hopkins IE: Manipulation of ventilator settings to prevent active expiration against positive pressure inflation. Arch Dis Child 1985; 60: 1036-1040
12. South M, Morley CJ: Synchronous mechanical ventilation of the neonate. Arch Dis Child 1986; 61: 1190-1195
13. Amitay M, Etches PC, Finer NN, et al: Synchronous mechanical ventilation of the neonate with respiratory disease. Crit Care Med 1993; 21: 118-124
14. Mehta A, Wright BM, Callan K, et al: Patient-triggered ventilation in the newborn. Lancet 1986; ii: 17-19
15. Mizuno K, Takeuchi T, Itabashi K, et al: Efficacy of synchronized IMV on weaning neonates from the ventilator. Acta Paediatrica Japonica 1994; 36: 162-166
16. Bernstein G, Heldt GP, Mannino FL: Increased and more consistent tidal volumes during synchronized intermittent mandatory ventilation in newborn infants. Am J Respir Crit Care Med 1994; 150: 1444-1448
17. Bernstein G, Mannino FL, Heldt GP, et al: Randomized multicenter trial comparing synchronized and conventional intermittent mandatory ventilation in neonates. J Pediatr 1996; 128: 453-463
18. Chen JY, Ling UP, Chen JH: Comparison of synchronized and conventional intermittent mandatory ventilation in neonates. Acta Paediatrica Japonica 1997; 39: 578-583
19. Marini JJ, Smith TC, Lamb VJ: External work output and force generation during synchronized intermittent mechanical ventilation: Effect of machine assistance on breathing effort. Am Rev Respir Dis 1988; 138: 1169-1179
20. Leung P, Jubran A, Tobin MJ: Comparison of assisted ventilator modes on triggering, patient effort and dyspnea. Am J Respir Crit Care Med 1997; 155: 1940-1948
21. Jarreau PH, Morielte G, Mussat P, et al: Patient-triggered ventilation decreases work of breathing in neonates. Am J Respir Crit Care Med 1996; 153: 1176-1181
22. Kacmarek RM, Hess D: Basic principles of ventilator machinery. In: Principles and Practice of Mechanical Ventilation. Tobin MJ (Ed). McGraw-Hill, New York, 1994, pp 65-110
23. Coates A, Stocks J, Gerhardt T. Esophageal manometry. In: Infant Respiratory Function Testing. Stocks J, Sly P, Tepper R, et al. (Eds). New York, John Wiley & Sons, 1996, pp 241-258
24. Bhutani VK, Sivieri EM, Abbasi S, et al: Evaluation of neonatal pulmonary mechanics and energetics: A two factor least mean square analysis. Pediatr Pulmonol 1988; 4: 150-158
25. Brochard L, Harf A, Lorino H, et al: Inspiratory pressure support prevents diaphragmatic fatigue during weaning from mechanical ventilation. Am Rev Respir Dis 1989; 139: 513-521
26. Agostini E: Volume-pressure relationship of the thorax and lung in the newborn. J Appl Physiol 1959; 14: 909-913
27. Kacmarek RM, Hess D: Basic principles of ventilator machinery. In: Principles and Practice of Mechanical Ventilation. Tobin MJ (Ed). New York, McGraw-Hill 1994, pp 65-110
28. Jubran A, Van de Graff WB, Tobin MJ: Variability of patient-ventilator interaction with pressure support ventilation in patients with chronic obstructive pulmonary disease. Am J Respir Crit Care Med 1995; 152: 129-136
29. Esteban A, Frutos F, Tobin MJ, et al: A comparison of three methods of gradual withdrawal from ventilatory support during weaning from mechanical ventilation. N Engl J Med 1995; 332: 345-350
30. Brochard L, Rauss A, Benito S, et al: Comparison of three methods of gradual withdrawal from ventilatory support during weaning from mechanical ventilation. Am J Respir Crit Care Med 1994; 150: 896-903
31. Nishimura M, Hess D, Kacmarek RM: The response of flow triggered infant ventilators. Am J Respir Crit Care Med 1995; 152: 1901-1909
|
Language: | English.
|
Document Type: | Clinical Investigations.
|
Journal Subset: | Clinical Medicine.
|
ISSN: | 1529-7535
|
NLM Journal Code: | 100954653
|
Annotation(s) | |
|
|